TM Cold Junction Compensator
|
VEREWA’s Cold Junction Compensators consist of an aluminum bloc with correctly controlled temperature. For temperature measurement with thermocouples they supply an exact reference temperature

|
 |
|
Cold Junction Compensation for up to 48 thermocouples
|
|
one or multiple type elements
|
|
Plastic or Steel Plate Box
|
|
General Purpose or Ex-area version
|
|
climatic proof version for more rigid requirements |
| reference Temperature
| 50°C (Standard), 60°C, 70°C (Option)
|
| accuracy:
| ±0.1°C / ∆10°C AT
|
| ambient temperature
|
-20° ... +45°C (50°C BT) -20 ... +55 C (60°C BT) -20° ... +65°C (70°C BT)
|
| temperature drift
| ±0.1°C / Δ10°C UT
|
| start-up time
| 60 min.
|
| thermo couples
| Fe-Ko, NiCr-Ni, PtRh-Pt (andere auf Anfrage)
|
| quantity
| 6 , 12 , 24 or 48
|
| mixed elements
| Option "g"
|
| climatic proof version
| Option "k"
|
| power supply
| 230 VAC, 110 VAC, 24 VAC, 50/60 Hz 24 VDC |
| Type
|
Conncections
|
No. of reference elements
|
Housing
|
| TM 6 K(m)I
|
6
|
6
|
plastic
|
|
|
|
|
|
| TM 6 K/I
|
6
|
6
|
plastic
|
| TM 6 K/II
|
6
|
12
|
plastic
|
| TM 6 K/III
|
6
|
18
|
plastic
|
|
|
|
|
|
| TM 12 K/I
|
12
|
12
|
plastic
|
| TM 12 K/II
|
12
|
24
|
plastic
|
| TM 12 K/III
|
12
|
36
|
plastic
|
|
|
|
|
|
| TM 24 K/I
|
24
|
24
|
plastic
|
| TM 24 K/II
|
24
|
48
|
plastic
|
|
|
|
|
|
| TM 48 K/I
|
48
|
48
|
steel plate
|
|
|
|
|
|
| TM 6 B/I
|
6
|
6
|
steel plate
|
| TM 6 B/II
|
6
|
12
|
steel plate
|
| TM 6 B/III
|
6
|
18
|
steel plate
|
|
|
|
|
|
| TM 12 B/I
|
12
|
12
|
steel plate
|
| TM 12 B/II
|
12
|
24
|
steel plate
|
| TM 12 B/III
|
12
|
36
|
steel plate
|
|
|
|
|
|
| TM 24 B/I
|
24
|
24
|
steel plate
|
| TM 24 B/II
|
24
|
48
|
steel plate
|
|
|
|
|
|
| TM 48 B/I
|
48
|
48
|
steel plate |
|
Ex-Version acc. VDE 0171/2.65 in Safety Version (Ex) s G 5 |
| TM 6 K(Ex)/I |
6 |
6 |
6 |
| TM 12 K(Ex)/I |
12 |
12 |
12 |
| TM 624K(Ex)/I |
24 |
24 |
24 |
|
|