Home    English    Deutsch    Français    Partners    Sitemap    Impressum  

 

 
Measuring Device for Dust Concentration D-R 300-40
 
Besonders empfindliches ­Messgerät für geringste Staubkonzen­trationen, speziell in Müllverbrennungsanlagen


   

 

Features

   

In-situ measurement directly in the flue gas flow

Automatic system tests and correction of measured values

Self-calibration in 4-h cycle

Optics and electronics in a hermetically sealed unit - no smoke gas can enter device

Maintenance-friendly, thanks to optimal purge air conduction in front of the heated optical end plates
Direct access to all parameters via the operator display
Automatic measuring range selection in accordance with 17. BImSchV. in relation 1:3:9.
 

Applications

   
Fine dust measurements in processes
Waste incineration

Filter monitoring and emission-value measuring in waste incineration and power plants

   

 

measurements

dust concentration

measuring ranges

0–1 mg/m3 ... 0–30 mg/m3 1),
optional 0–300 mg/m3 with measuring range switching

measuring principle

back scattering

flue gas temperature

above dew point up to 320°C,
optional (depending on application) up to600°C

flue gas pressure

-50 up to +20 hPa

duct diameter

0.3 up to 4 m

ambient temperature

-20 up to +50°C

Protection

IP65

measuring outputs

2 x 0/4–20 mA/500 Ohm,
optional measuring range switching

digital outputs

3 relay outputs,
permissable load 250 V / 100 VA

digital inputs

1 potential free input

accuracy

<1% of measuring range

detection limit

<1% of measuring range

reference point drift

<0.2% of measuring range/month

zero point drift

<0.2% of measuring range/month

supply voltage

115 / 230 VAC, 50 / 60 Hz, 50 VA

dimensions (H x W x D)

measuring head 565 x 310 x 200 mm

weight

18 kg

remarks

1) after gravimetric calibration

purge air supply

purge air quantity

approx. 80 m3/h

supply voltage

115/230 VAC, 50/60 Hz,
0.37 /0.43 kW

dimensions (H x W x D)

350 x 550 x 500 mm

weight

12 kg

protection

IP54

More information 


 