Volume Flow Measuring System D-FL 200
Measuring system for ultra-sonic measuring of velocity and volume flow, especially for wet and aggressive smoke emissions (waste incineration).
|
Measuring system for ultra-sonic measuring of velocity and volume flow, especially for wet and aggressive smoke emissions (waste incineration)

|
|
|
Features |
| |
|
 |
In-situ measuring method |
 |
Measurement possible below dew point and for high dust concentrations |
 |
Continuous measurement of normal volume flow and gas velocity |
 |
Automatic zero point and reference point control |
 |
Direct connection for temperature and pressure correction |
 |
Parameter input via keyboard or PC |
 |
Continuous temperature measuring |
| |
|
Applications |
| |
|
 |
Volume flow measuring at low speeds |
 |
Plants with damp and/or aggressive exhaust gas, e.g. in waste incineration plants. |
 |
Volume flow measurement at high dust content |
| |
|
|
|
|
measurements
| flue gas velocity, volume flow 1), temperature
|
|
measuring ranges
|
0–3000000 m3/h / 0–40 m/s 0–400°C
|
|
measuring principle
|
acoustic propagation delay
|
|
flue gas temperature
|
0–200°C, optional higher
|
|
flue gas pressure
|
-50 up to +20 hPa, optional higher
|
|
duct diameter
|
0,7–10 m, temperature dependent
|
|
ambient temperature
|
-20 up to +50°C
|
|
protection
|
IP65
|
|
measuring outputs
|
2 x 0 / 4–20 mA / 500 Ohm, optional Modbus RTU (RS 485)
|
|
digital outputs
|
3 relay outputs, permissable load 250 V, 100 VA
|
|
digital inputs
|
-
|
|
accuracy
|
<2% of measuring range
|
|
detection limit
|
<0.3% of measuring range |
|
reference point drift |
<0.3% of measuring range/month |
|
zero point drift |
<0.2% of measuring range/month |
|
supply voltage |
115 / 230 VAC, 50 / 60 Hz, 50 VA |
|
dimensions |
standard measuring head: 190 Ø x 570 mm |
|
weight |
17 kg |
|
remarks |
1) optional pressure and temperature correction |
|
purge air supply |
|
purge air quantity |
approx. 80 m3/h |
|
supply voltage |
115 / 230 V, 50 / 60 Hz, 0.37 / 0.43 kW |
|
dimensions (H x B xT weight |
350 x 550 x 500 mm 12 kg |
|
protection |
IP54 |
More information 
|