Visibility Monitor D-RV 290
|
Non-contact, continuous monitoring of visibility levels

|
|
|
Features |
| |
|
 |
Use of autocollimation (double-pass) principle doubles the sensitivity of the monitor |
 |
Suitable for cold-fire detection |
 |
Easy installation and menu-driven operation |
 |
Window contamination correction performed automatically |
 |
Entspricht den Umweltprüfungen nach IEC 68-1 |
 |
Long maintenance intervals |
 |
Rugged V4A stainless steel housing, IP65 enclosure rating |
 |
Complies with environmental testing according to IEC 68-1 |
 |
Profibus dp (option) |
|
|
|
measuring principle |
Transmission |
|
path length |
up to 12 m |
|
light source |
SWBD Super Wide Band Diode |
|
measuring range |
0 - 15/km |
|
error limit |
<2% of measuring range |
|
integration time |
5 -1800 s |
|
max. perm. ambient temperature |
-20 up to55°C |
|
max. deviation from optical axis |
0.35° |
|
output signal |
0-20 mA/500 Ohm, optional Modbus |
|
6 status contacts |
- limit exceedence - maintenance, - fault etc. |
|
conformity |
IEC 68-1 |
|
MTBF |
approx. 10.000 Std. |
|
supply voltage |
95 - 264 V, 48 - 62 Hz |
|
power consumption |
approx. 30 VA |
|
protection |
IP65 |
|
housing |
V4A stainless steel (1.4571) |
|
weights |
measuring head: approx. 10 kg reflector: approx. 7 kg |