D-R 220 properties - Which ranges can I realize?

The D R-220 is an optical Transmission meter. The internally measured parameter is transmission.

The physical range of D-R 220 is:


  • Transmission: 100 .. 2.5% T

 

this physical range corresponds to


  • Opacity: 0 .. 97.5%
  • Extinction: 0 .. 1.6 EXT


The 4-20 mA analog output of the D-R 220 can be assigned to customer requirements by help of DIP switches as follows: 


  • 4-20 mA corresponds to 0 .. 25% OP 
  • 4-20 mA corresponds to 0 .. 50% OP
  • 4-20mA corresponds to   0 .100% OP 


  • 4-20 mA corresponds to 0 .. 0.2 EXT 
  • 4-20 mA corresponds to 0 .. 0.4 EXT
  • 4-20 mA corresponds to 0 .. 1.6 EXT

 

D-ESI 100 configuration software also allows to assign any interval within the base ranges.

Last update on 31. October 2010 by Axel Kumm.

Go back