D-FL 100 Volume flow measuring system

Suitability-tested and certified impact pressure system to measure velocity and volume flow of dry flue gas or process gas in pipes or ducts.

  • In situ measurement, continuous measurement
  • Allows calibration to measure the volume flow
  • Cross duct, half duct and single point versions
  • Also suitable for thick-walled stone / insulated ducts
  • Sensor in contact with sample gas, backpurge as an option
  • Automatic zero check as an option
  • Easy installation, adjustment and maintenance without a PC
  • Local control unit with LCD screen for data display as option
  • Includes temperature and pressure sensor as option
  • Normalization of the flow measurements as an option
  • Very low maintenance
  • Applications
  • Certifications
  • Technical data
  • Downloads

Suitable for velocity and volume flow  measurement

 

  • at incinerators with dry fluegas in general
  • at installations in accordance with 2000/76/EC WID / 17 BImschV
  • at garbage, hazardous waste and sewage sludge incinerators,
  • at facilities for cement production
  • at installations in accordance with 2001/80/EC LCPD / 13 BImschV / Clean Air Act
  • at power stations with gas, oil, coal or co-firing
  • at facilities pursuant to 27th BImschV
  • for processes, Ex zones, high temperature or high pressure applications
  D-FL 100 Application Data
measurements impact differential pressure
flow velocity
volume flow, at operating conditions or normalized
sample gas air, flue gas, process gas
flow velocity** 2..3 to 10 / 20 / 40 m/s others on request
duct diameter*** 0,5 - 10 m
sample gas temperature* -20 to 450 / 850°C*
dust load < 30 mg/m3, type 1 (24x22mm) without backpurge
< 100 mg/m3, type 2 (54x50mm) without backpurge
< 150 mg/m3, type 3 (100x90mm) without backpurge
sample gas pressure
(relative to ambient pressure)
-700 to +1,000 hPa, others on request
sample gas moisture 0 - 95 % rel. humidity (no condensation allowed)
ambient temperature -20 to 50 °C, others on request
conformity 2000/76/EG WID / 17. BImschV
2001/80/EG LCPD / 13. BImschV
27. BImschV
  D-FL 100 Technical data
measuring principle measurement of impact differential pressure at a multi hole probe, calculation of gas velocity and volume flow taking into account cross section of the duct, sample gas temperature, pressure and density
type in situ, measurement cross stack, half duct or single point, probe is in contact with sample gas
system components D-FL 100 S probe
D-FL 100 A adaptor
D-FL 100 UH valve*
D-FL 100 DDM-H differential pressure transmitter
D-FL 100 ADM-H absolute pressure transmitter*
D-XT temperature transmitter*
accessories
measuring range 0 to 40 m/s,
0 - 4...3,000 * 1000 Nm3/h
any range within the measuring range can be assigned to the analog output
resolution 0.1 m/s
expanded uncertainty
EN14181 / EN ISO14956 / EN15267-3
better than 0.9 m/s at range 0 - 20 m/s,
the accuracy depends on installation, measuring path, flow profile and the accuracy of the reference measurement used for calibration
process connection 1 to 2 mounting pipes with flange
DN40 PN6 (System 1), pipe ID=43.1 mm, OD=48.3 mm
DN65 PN6 (System 2), pipe ID=70.3 mm, OD=76.1 mm
DN100 PN6 (System 3), pipe ID=107.1 mm, OD=114.3 mm
others on request