| Common Data | |
| Outer tube diameter Outer tube length up to 4000 mm Outer tube length from 4000 mm |
65 mm 70 mm For the stainless steel version always dia. 70 mm |
| Flame length (depending on the gas) |
max. 1200 mm |
| Outer tube length (in 10 mm increments from - to) |
240 - 15000 mm |
| Gas port | Rp 3/4, top or bottom |
| Gas inlet pressure | 50 - 150 mbarg |
| Air port | Rp 1½, rotatable 4 x 90° |
| Air operating pressure | 20 mbarg, plus another 13 mbarg for every m of outer tube length |
| Power head | |
| for zone 2: II 3G Ex nC IIC T5 Gc | |
| for zone 22: II 3D Ex tc IIIC T 100 °C | |
| Ignition | 5 kV |
| Ambient temperature | - 20 °C to + 60 °C |
| Protection rating | IP 65 |
| Models | |
| with integrated spark transfomer and ionisation flame monitor for intermittent operation | ZXA1... |