| Common Data | |
| Outer tube diameter Outer tube length up to 4000 mm Outer tube length from 4000 mm |
48 mm 50 mm For the stainless steel version always dia. 50 mm |
| Flame length (depending on the gas) |
max. 600 mm |
| Outer tube length (in 10 mm increments from - to) |
240 - 15000 mm |
| Gas port | Rp 1/2, left or right |
| Gas inlet pressure | 50 - 150 mbarg |
| Air port | Rp 1, rotatable 4 x 90° |
| Air operating pressure | 10 mbarg, plus another 10 mbarg for every m of outer tube length |
| Power head (not ZG0) | |
| Ignition | 5 kV |
| Ambient temperature | - 30 °C to + 60 °C |
| Protection rating | IP 54 or IP 65 |
| Models | |
| without electrical components | ZG0... |
| with integrated spark transformer | ZT0... |
| with integrated spark transformer and ionisation flame monitor for intermittent operation | ZA0... |
| with integrated spark transformer and ionisation flame monitor for continuous operation | ZDA0... |