Gas Fired Igniter

Heat Release max. 2 kWtl_files/dg/images/logos/hegwein_150.gif

  • Applications
  • Technical Data
  • Downloads
  • Ignition of gas burners up to 500 kW
  • Application in heat treatment plants and where space is limited
Common Data  
Outer tube diameter 15 mm
Flame length
(depending on the gas)
max. 80 mm
Outer tube length
(in 120 mm increments from - to)
120 – 2400 mm
Gas port Rp 1/4
Gas inlet pressure 20 +/- 2 mbarg
Air port Rp 1/4
Air operating pressure 20 +/- 2 mbarg
Power head (not ZGF)  
Ignition 5 kV
Ambient temperature - 30 °C to + 60 °C
Protection rating IP 54 or IP 65
Models  
without electrical components ZGF...
with integrated spark transformer ZTF...
with integrated spark transformer and ionisation flame monitor for intermittent operation ZAF...
with integrated spark transformer and ionisation flame monitor for continuous operation ZDAF...