Gas Fired Igniters for Hazardous Areas

Heat Release max. 2/4 kWtl_files/dg/images/logos/hegwein_150.gif

  • Applications
  • Technical Data
  • Downloads
  • Application in hazardous areas, zone 1 or zone 21
Data  
Outer tube length ZAVEX/F...
(in 120 mm increments from - to)
120 - 2400 mm
Outer tube length ZAVEX/U...
(in 10 mm increments from - to)
120 - 4000 mm
Gas port Rp 3/8
Gas inlet pressure
ZAVEX/F...
20 +/- 2 mbarg
Gas inlet pressure
ZAVEX/U...
20 mbarg, plus another 1 mbarg for every 2 m of outer tube length
Air port Rp 3/8
Air operating pressure
ZAVEX/F...
20 +/- 2 mbarg
Air operating pressure
ZAVEX/U...
20 mbarg (to 2 m), plus another 5 mbarg for every m of outer tube length
Power head  
  for zone 1: II 2G Ex de IIB T4 or II 2G Ex de IIC T4
  for zone 21: II 2D Ex tD A21 IP65 T95°C
Ignition 5 kV
Ambient temperature - 40 °C to + 60 °C
Protection rating IP 65
Models  
Heat release 2 kW ZAVEX/F...
Heat release 4 kW ZAVEX/U...

Go back