Ignition Lances

For burners and processes.tl_files/dg/images/logos/dg_smitsvonk.gif

 

  • High temperature (775 °C) ignition cable with connector and SST protection hose
  • High temperature (775 °C) thermocouple cable with connector and SST protection hose
  • SST junction box for ignition or thermocouple signal
  • Low temperature ignition cable
  • Low temperature thermocouple cable
  • Ignition and control unit
  • Applications
  • Technical Data
  • Downloads
  • Burners and processes
Ignition lances
for burners
and processes
     
diameter 17.2 mm 17.2 mm 15 mm
type 17.2/L/TP14/12 17.2/L/TP14/12-JB 15.7/L/TP12/JB
design straight straight straight
length L 200–1000 mm:
multiple of 100 mm,
1000–2000 mm:
multiple of 100 mm,
2000–3000 mm:
200 mm intervals
200–1000 mm:
multiple of 100 mm,
1000–2000 mm:
multiple of 100 mm,
2000–3000 mm:
200 mm intervals
200–1000 mm:
multiple of 100 mm,
1000–2000 mm:
multiple of 100 mm,
2000–3000 mm:
200 mm intervals
tube material 310 SST 310 SST 316 SST
electrical connection M25 easy fit connector
material: 316 SST
junction box
material: aluminium
junction box
material: aluminium
mechanical connection
option
none
flange or thread
none
flange or thread
none
flange or thread
option - flexible lance
- special bent shape
- mounting adapter
- ATEX II2G EEx dIIC T6
- flexible lance
- special bent shape
- mounting adapter
- ATEX II2G EEx dIIC T6
- flexible lance
- special bent shape
- mounting adapter
- ATEX II2G EEx dIIC T6

Go back