Ignition and control unit for flares.
| Ignition Units for Pilot Burners of Flares (longer distance) Common Data | |
| function | ignition and flame detection for pilot burner(s) or ignition lance(s) |
| power supply | 115 or 230 Vac Option 24 Vdc |
| ignition | 100% electronic, type SVECU |
| spark energy | 9 or 18 J |
| spark tension | 3000 Volt |
| spark frequency | 0,5 or 2 Hz depends on type pilot burner or lance. |
| flame detection | thermocouple relay type K |
| control | by small PLC |
| enclosure | IP66 general purpose or explosion proof IIB(ATEX), option: explosion proof for IIC |
| material | 304 SST for IP66 enclosure, cast aluminium for ex-proof enclosure, option: SST enclosure |
| temperature range | -20 to 55 for explosion proof -20 to 60 °C for IP 66 Option for -40°C |
| LED signal lamps | yellow power on, green for pilot on, red for pilot off, red for ignition failure |
| switches | main power isolator, start, stop, reset and lamp test |
| contacts | pilot on/off, ignition failure, option for 4–20 mA for t/c signal |
| max. distance | 250 meter option for 500 meter |
| explosion proof type |
safe area type | |
| for 1 pilot burner or ignition lance | SVECU X/2-EJB5-H4D4ST-L-CR-PH | SVECU X/2-AE1008-H4D4ST-L-CR-PH |
| for 2 pilot burners or ignition lances | 2SVECU-X/2-2EJB5-H4D6S2T-L-CR-PH | 2SVECU-X/2-AE1010-H4D6S2T-L-CR-PH |
| for 3 pilot burners or ignition lances | 3SVECU X/2-2EJB5-H4D8S3T-L-CR-PH | 3SVECU X/2-AE1012-H4D8S3T-L-CR-PH |
| for 4 pilot burners or ignition lances | 4SVECU X/2-2EJB5-H4D10S4T-L-CR-PH | 4SVECU X/2-AE1014-H4D10S4T-L-CR-PH |